| Application
H03VV-F , H03VVH2-F cable types are
especially suited to use on small appliances with low
mechanical stress and for connection for light household
appliances, e.g. kitchen utensils, desk lamps, floor
lamps, vacuum cleaners, office machines, radios, etc.,
as far as this cable is admitted to the relevant specifications
of the equipment.
These cables are not permitted to use with cooking or
heating apparatus.
Cables are not suitable for outdoor use or use of industrial
or farmer machineries.
Construction
• Bare copper, fine wire conductor, bunch stranded
as per VDE 0295 cl.5 (HD 383)
• PVC core insulation YI2 asper DIN VDE 0207 part4(HD
21.1 TI2)
• Cores colour coded to DIN VDE 0293 . (HD 27)
• Seven and more cores' number coded and one green-yellow
earth core
• Cores layed up by H03VV-F, and laid parallel byH03VVH2-F
• PVC outer jacket YM2 as per DIN VDE 0207/5(HD21.1
TM2), available in black, white or as per requirement
• PVC self- extinguishing, test method B according to
DIN VDE 0472 part 804 (HD 405.1)
Technical data
• Temperature range
- stationary -40°C to +70°C
- flexing - 5°C to +70°C
• Working voltage: Uo /U 300/300V
• Max. permissible operating voltage in three-phases
and one-phase:
- AC system Uo /U 330/330V
- DC system Uo /U 495/495V
• Test voltage 2000V
• Specific Insulation resistance
- at 70°C min. 1010
Ω x cm
• Bending radius 6 x Ø
kabel
|