Application
TK59...M is being applied to local
telephone network for subscriber lines.
It is laid directly into the ground and cable ducts.
The use of this cable in power purposes is not permitted.
Construction
Conductor is a soft annealed copper wire of 0.4mm;0.6mm
and 0.8mm diameter
Insulation is of cellular PE, type EETI ,according
MKS N.CO.195 and solid PE for skin
Four different coloured insulated conductors are twisted
to star quad which is the basic element of this cable.
Cable core is made of concentric or group twisted
star quads.
Core filling is made of petro-jelly
Core wrapping is realized with two impregnated paper
tapes with orange thread under them as the mark of FKN.
The sheath of the cable is made of aluminium tape
covered on both sides with a layer of ethylene
Technical data
Temperature range
- during operation -5°C to + 50°C
- before and after installation-30°C to + 50°C
Conductor Ø
mm 0,4; 0,6; 0,8
Loop resistance max.
at 20°C Ω/km 300; 130; 73,2
Loop resistance mean
value at 20°C Ω/km 290; 126; 72
Insulation resistance
min at 20°C (MΩkm) 5000
Mutual capacity, max at 800 Hz
- 0,4 - 90% (nF/km) 36
-
100% (nF/km) 38
- 0,6 - 80% (nF/km) 38
-
95% (nF/km) 40
-
100% (nF/km) 42
- 0,8 - 80% (nF/km) 38
-
95% (nF/km) 40
-
100% (nF/km) 42
Capacitance unbalance max. 800 Hz
- K1 - 100% (pF/300m) 800
- 98% (pF/300m) 400
- 95% (pF/300m)
- K9-12 - 100% (pF/km) 300/502
- 95% (pF/300m) 100/302
- e9-12 - 100% (pF/km) 800
Dielectric strength
- (AC) 2 min. core/core (V) 500
Attenuation at 800 Hz and 20°C οπθαλ.
- at cable with 1 quad (mN/km) 150; 105; 80
- for other cables (mN/km) 150; 105; 80
Permitted bending radius, min. (mm) 15x
Ø kabel
|