Application
These cables are suitable for telephone
stations and sub-extensions, for signal and data trans-mission.
This cable type with electrostatic screening (St) protects
the transmission circuits against extern electrical
interferences. Installation cables laid up in pairs
are preferably used for indoor telecommunication installation
in dry and damp places, but also in the open for fixed
installation on outer walls of buildings. The use of
this cable is not allowed in energetic purposes.
Construction
• Bare copper conductor, solid, 0,6 and 0,8mm Ø
according DIN VDE 0295
• PVC core insulation, compound type YI1, as per DIN
VDE 0207/4,
• Insulation colour and pair identification as per
DIN VDE 0815
• Insulated cores are twisted in pairs and the pairs
are stranded in concentric layers
• Core wrapping with plastic tape
• Electrostatic screen (St) of plastic coated aluminium
foil and drain wire
• PVC outer jacket grey RAL 7032, compound type YM1
as per DIN VDE 0207 part 5.
• PVC mass for insulation and jacket is self extinguishing,
test method B according to VDE 0472 part 804.
Technical data
• Temperature range
- flexing -5°C to + 50°C
- stationary -30°C to + 70°C
• Conductor Ø
mm 0,6; 0,8
• Loop resistance max.
at 20°C max Ω/km 130; 73,2
• Insulation resistance
value at 20°C min ΩW/km 100; 100
• Mutual capacitance
- at 800 Hz max nF/km 10010; 10010
• Capacitance unbalances
- at 800 Hz max pF/100m 30021; 30021
• Line attenuation 800 Hz max dB/km 1,7; 1,1
• Test voltage
- core/core V 800;800
- core/screen V 800;800
• Working voltage (peak value) V 30030; 30030
• Bending radius
- during delivery 7,5 x Ø
kabel
- single bending without tension2,5 x Ø
kabel
- repeated bending under tension 7,5 x Ø
kabel
1) this value may be extended by 20% with a make-up
to 4 pairs.
2) 20% of the values are allowed from 300 to 500 pF,
but only one value with 500 pF.
3) short time operation (6s/min) up to 600 V permitted.
|